Structural integrity assessment for hardware building along Ntinda - Kisaasi road

Quick Info

  • Project Name: Structural integrity assessment for hardware building along Ntinda - Kisaasi road
  • Categories: Structural Integrity Assessment
  • Period: January, 2022
  • Location: Ntinda-Kisaasi Road

Services Provided

  • Trial pits exploration to a depth of 2m outside and exposing the column pads, logging each trial pit.
  • Conducting DCP tests near each excavated test pit to a total depth of 2m
  • Concrete strength assessment using rebound Hammer
  • Reinforcement Identification in the structural Elements
  • Assessing the dimensions of the structural Elements
  • Carrying out laboratory tests namely; PSD, Hydrometer test, Atterberg limits, Compaction.
  • Data Entry and Result Analysis
  • Preparation of a Structural integrity Investigations Report